eo_logo
 
Product added to cart

Nikon Tube Lens to C-Mount Holder

See More by Nikon

Nikon Tube Lens to C-Mount Holder (#11-150)

×
Stock #11-150 5-7 Days
×
Quantity Selector - Use the plus and minus buttons to adjust the quantity. +
NT$5,390
Qty 1+
NT$5,390
Volume Pricing
Request Quote
下載產品資料

Product Details

Type:
Microscope Accessory

Physical & Mechanical Properties

Length (mm):
37.70
Outer Diameter (mm):
50.00

Threading & Mounting

Mounting Threads:
1" x 32 TPI (Male and Female)

Additional Info

Note:
Requires adapter #11-148 to connect Nikon objective

Regulatory Compliance

RoHS:
Certificate of Conformance:

產品系列說明

  • 出眾的色彩再現能力
  • 長工作距離,高數值孔徑
  • 高對比度及最小光斑
  • 無應變

Nikon CFI60 無限補正亮場物鏡結合 Nikon 光學技術,可因應進階成像需求。Nikon CFI60 無限補正亮場物鏡具備 60mm 等焦距離與大筒徑,能提供更高的亮度,以及工作距離與數值孔徑的最高可能組合(具備採光能力)。這款物鏡經過精心設計,可在整個視場對橫向與軸向色像差進行補正,產生具有高對比度及高分辨率的影像。

成像鏡筒配件(#58-520)可用於將遠場補正物鏡發出的光聚焦到影像平面上。若要取得最佳效能,成像鏡筒與物鏡支架之間的距離應保持在100 - 200mm之內。藉由此間隔,可在光路內插入配件以因應特定需求。這款成像鏡筒可使用 Nikon 收斂鏡頭和 C 接口支撐架 (#11-150) 整合至 C 接口系統。

注意: 必須移除四個凹頭帽螺釘,才能將成像鏡筒置入 Nikon 成像鏡筒的 C 接口支撐架。

Title 比較庫存號碼  價格 Buy
Nikon Tube Lens to C-Mount Holder #11-150 NT$5,390   Request Quote
  • 5-7 Days
    ×
Nikon 200mm Tube Lens #58-520 NT$16,660   Request Quote
  • 聯絡我們
    ×

技術資訊

Dimensions
  5X 10X 20X 50X 100X
A 29.0mm 29.0mm 29.0mm 30.0mm 30.0mm
B 36.3mm 42.4mm 40.9mm 48.9mm 55.4mm
C 20.0mm 17.0mm 22.5mm 21.5mm 21.5mm
Filter

了解顯微物鏡

想了解更多關於顯微物鏡的知識嗎?了解愛特蒙特光學用於建立顯微物鏡的不同組件、關鍵概念和規格。

現在查看

Multiphoton Microscopy

Multiphoton microscopy is ideal for capturing high-resolution 3D images with reduced photobleaching and phototoxicity compared to confocal microscopy.

現在查看

Confocal Microscopy

Confocal microscopy provides high resolution, elimination of out-of-focus glare due to spatial filtering, and reduction of light-induced damage to the sample.

現在查看

Infinite Conjugate Tube Length

Understanding Infinity Corrected Objective Resolving Power and Magnification

Microscopes are used in a variety of fields and applications. To understand how resolving power, magnification, and other aspects work, read more at Edmund Optics.

現在查看

使用無限校正物鏡和管鏡

想要使用無限遠校正物鏡來拍攝影像嗎?您需要一個管透鏡才能做到這一點!了解愛特蒙特光學的原因和工作原理。

現在查看

What is an "in-line" microscope?

What is an infinity-corrected objective?

Can I use an infinity-corrected objective in my microscope to get a longer working distance?

What is "DIN" and "JIS"? What is the difference between them?

I’m using the MT-1 Accessory Tube Lens and MT-1/MT-2 C-Mount Adapter. Two thin brass rings came with the adapter. How are they used?

What is the significance of the field number of an objective and what is it dependent on?

Plan Objective

Semi-Plan Objective

Tube Lens

未來的顯微鏡物鏡

Advances in Microscopy Tackle the Challenges of the Future

現在查看

Optical Microscopy Application: Brightfield Illumination

Looking to use a simple technique for optical microscopy? Check out this article on brightfield illumination to find out more at Edmund Optics.

現在查看

Optical Microscopy Application: Darkfield Illumination

Darkfield illumination is the opposite of brightfield illumination. Find out how darkfield differs from brightfield in optical microscopy at Edmund Optics.

現在查看

Optical Microscopy Application: Phase Contrast

Think you know all the advantages for using phase contrast in optical microscopy? Advantages, image appearance, and technical details can be found at Edmund Optics.

現在查看

What is the difference between Achromatic, Semi-Plan and Plan objectives?

You have a variety of Mitutoyo Tube Lenses (MT-4, MT-1, and MT-2). How can you connect them to a Mitutoyo objective and C-mount camera?

I have an MT-L Accessory Tube Lens but I am unsure about mounting it to my objective and C-Mount camera. Can you explain how it works?

Achromatic Objective

Apochromatic

Confocal Microscopy

DIN (Deutsche Industrie Norm)

Periplan Eyepiece

Optical Cage System Application: Digital Video Microscope

Are you looking to simplify the assembly of a digital video microscope? Find out how a TECHSPEC Optical Cage System allows for quick build at Edmund Optics.

現在查看

Optical Microscopy Application: Differential Interference Contrast

Differential interference contrast (DIC) is one of the polarization techniques that can be used in optical microscopy. Learn about this technique at Edmund Optics.

現在查看

Field Number

Light Sheet Microscopy

Light sheet fluorescence microscopy uses a 2D laser sheet to illuminate a thin slice of the sample and excite fluorescence, reducing phototoxicity and damage.

現在查看

Optical Cage System Application: Differential Interference Contrast (DIC) Digital Microscope

Differential interference microscopy enhances the contrast of object features that are otherwise difficult to observe using brightfield microscopy.

現在查看

Darkfield Illumination

Diffraction Limit

Parfocality

Digital Video Microscope Objective Setups

Digital video microscopes use a camera to capture and record images. Read more about the components needed to assemble a video microscope at Edmund Optics.

現在查看

Optical Microscopy Application: Fluorescence

Wondering how fluorescence microscopy works? Find out about the technique, systems, and more at Edmund Optics.

現在查看

Brightfield Illumination

Field of View (FOV)

Magnification

Numerical Aperture (NA)

Fluorescence Microscopy: In-Line Illumination with Imaging Filters

Want to know about fluorescence microscopy? Read this article by a Biomedical Product Line Engineer at Edmund Optics to learn more.

現在查看

Refraction

 
Sales & Expert Advice
 
or view regional numbers
Easy-to-Use
QUOTE TOOL
enter stock numbers to begin